Install an M-8S in your rack, and the eight outlets in the rear panel will power up in sequence and protect all your equipment up to a 15-amp load.
Merit M-8S Power Sequencer is the perfect low-cost AC power solution for any rack mount system where power sequencing is desired.
Install an M-8s in to the top slot of your rack, and the six delayed outlets in the rear panel will power up sequentially and protect all your equipment up to a 15-amp load.
Includes 3 delayed outlet banks – each with 2 outlets – plus 2 unswitched outlets.
FEATURES
- Power Sequencing
- Prevents excessive inrush currents.
- Six sequenced rear panel outlets (in three groups), two unswitched rear panel outlets, and one front panel unswitched outlet.
- Momentary and maintained sequencing via rear panel terminal block or front panel switch (momentary only).
- Noise Filtration
- Noise filtering to reduce radio frequency and electromagnetic interference.
- Surge Protection
- Ensures equipment stays safe.
- 9 Total Outlets
- Eight rear panel outlets and one front panel convenience panel outlet.
- 15 Amp Rating
- 15 amp rating, with circuit breaker.
- “Protection OK” Indicator
- Front panel indicator LEDs for Outlet Banks, Protection OK and Power Status.
- Wall Wart Spacing
- Rear outlets have been spaced to accommodate even the bulkiest of wall warts and adapters.
- All settings and configurations available on rear panel.
- Mass 5.3 lbs.
SPECIFICATIONS
- Maximum AC Current Rating 15 Amps, 120 VAC (Thermal breaker)
- AC Cord 14AWGx3, 10 feet, black, fixed, NEMA 5-15P plug
- Convenience Outlet (Front Panel) 1 Un-switched NEMA 15-5R
- Rear Panel Outlets 2 Un-switched NEMA 5-15R (1 duplex)
- 6 Sequenced NEMA 5-15R (3 duplexes, each controlled by separate relay)
- AC Surge Protection Merit Class (sacrificial)
- Spike Protection Mode Line to neutral, zero ground leakage
- Max Continuous Operating Voltage 130V RMS
- Max Clamp Voltage 500 Volts Peak
- Peak Impulse Current 12,000 Amps
- Energy Rating (2 X 820µS) 225 Joules
- AC Filtering Pi LCR Filter
- Noise Attenuation >26dB, 100 Khz to 1 MHz
- Operating Temperature Range 5C (40F) to 40C (105F) degrees
- Humidity Range <90% rH (Relative Humidity)
- Rocker Switch Front panel, Sequence (ON, OFF)
- Thermal Circuit Breaker Front panel, push to reset
- Front panel indicators Delay 1, Delay 2, Delay 3, Power, Protection OK
- Control/Status/Triggering (Rear Panel) Rear Panel DIP Switches: 12V Mode On/Off,
- GND Mode On, Momentary/Maintained
- Potentiometer Rear panel, time calibration fine tune delay adjust
- Remote Terminal +5-30VDC In, 12VDC (12mA) Out
- Remote Terminal Phoenix type 4-Pin Connector with Screw terminals; +12V, STAT, REM, GND (Class 2 Wiring)
- Size 1.75” X 19.00” X 6.5” (HWD) – ANSI 1RU